GW
Relay |
· 1 Form C, 2 Form C Contact
Form
· High
contact load 30A
· High reliability. |
1. Contact Data
Contact Form |
1A,
1B, 1C,
|
2A, 2B, 2C
|
Initial
Contact Resistance |
50m¥Ø(at 1A 24VDC)
|
Contact Material |
Silver
Alloy
|
Contact Ratings |
30A 250VAC, 30A 30VDC
18A 380VAC, 16A 440VAC
|
Max. switching voltage |
48VDC
/ 440VAC
|
2. General Data
Insulation Resistance |
Min. 500M¥Ø 500VDC |
Operate
Time |
Max.
20msec. |
Release Time |
Max. 15msec. |
Dielectric
Strength
Between |
Open Contacts |
1,500VAC
1min. |
Contacts and coil |
2,500VAC 1min. |
Terminal Type |
Plug-in, Flange |
3. Coil Data
VDC
Nominal
Voltage
VDC |
Pick-up
Voltage
VDC |
Drop-out
Voltage
VDC |
Standard Coil
Resistance
at 20¡É |
6 |
4.50 |
0.6 |
18±10% |
9 |
6.75 |
0.9 |
40.5±10% |
12 |
9 |
1.2 |
72±10% |
18 |
13.5 |
1.8 |
162±10% |
24 |
18 |
2.4 |
288±10% |
48 |
36 |
4.8 |
1,125±10% |
60 |
45 |
6.0 |
1,800±10% |
110 |
82.5 |
11.0 |
6,050±10% |
VAC
Nominal
Voltage
VAC |
Pick-up
Voltage
VAC |
Drop-out
Voltage
VAC |
Coil
Resistance
|
6 |
4.8 |
1.8 |
3.15±10% |
9 |
7.2 |
2.7 |
7.1±10% |
12 |
9.6 |
3.6 |
12.6±10% |
18 |
14.4 |
5.4 |
28.4±10% |
24 |
19 |
7.2 |
50.4±10% |
48 |
38.4 |
14.4 |
113±10% |
110 |
88 |
33 |
1,100±10% |
220 |
176 |
66 |
4,200±10% |
4. Ordering Code
5. Overall And Mounting Dimensions
6. Useful Curve
|