ID:     PW:   
Korean English
ȸ»ç¼Ò°³ Á¦Ç°¾È³» ±â¼úÀÚ·á °Ô½ÃÆÇ ÆǸŴ븮Á¡ »çÀÌÆ®¸Ê

Telecom
Power
General Purpose
Automotive
SSR(Solid State Relay)
Time
etc
Home > Product > Power    
    Socket Packing Cross Reference
Power
HANDOUK LOGO
 HE Relay

 1 Form A / 1 Form C Configration
 10A 120/240VAC, 5A 240VAC/30VDC
 Subminiature, PCB layout
 Sealed relays

1. Contact Data

Contact  Form 1 Form A (SPST) 1 Form C (SPDT)
Contact  Material Silver Alloy
Contact  Ratings Standard High Capacity 3A 240VAC
3A 30VDC
10A 120VAC
5A 240VAC, 5A 30VDC
10A 250VAC
10A 240VAC
Max. switching voltage 250VAC / 30VDC
Max. switching current 10A
Max. switching power 1200VA / 150W
Contact Resistance 100m¥Ø Max at 6VDC 1A
Life Expectancy Electrical 100,000 Operations (at 30 Operations / minute)

Machanical

10,000,000 Operations

2. General Data

Insulation Resistance 100M¥Ø, Min at 500VDC
Dielectric Strength
Between
Open Contacts 750VAC (for one minute)
Contacts and coil 2,500VAC (for one minute)
Operate Time 8ms
Release Time 5ms
Temperature Range -40¡Éto+70¡É
Shock Resistance Malfunction 10g
Mechanical 100g
Vibration Resistance 10-55Hz, 1.5mm
Humidity 40% ~ 85%RH
Dimensions(mm) 20 x 10.6 x 15.6
Weight Approx. 6g
Safety Standard cULus UL E197546
TUV R50162334

3. Coil Data

Nominal
Voltage
VDC
Pick-up
Voltage
VDC
Drop-out
Voltage
VDC
Max. Allowable
Voltage VDC
( at 20 ° C )
Coil Resistance
Standard
(0.45W)
Sensitive
(0.20W)
3 2.25 0.3 3.9 20 +/-10% 45 +/-10%
5 3.75 0.5 6.5 56 +/-10% 125 +/-10%
6 4.50 0.6 7.8 80 +/-10% 180 +/-10%
9 6.75 0.9 11.7 180 +/-10% 405 +/-10%
12 9.00 1.2 15.6 320 +/-10% 720 +/-10%
24 18.0 2.4 31.2 1,280 +/-10% 2880 +/-10%
48 36.0 4.8 62.4 5,100 +/-15%  

4. Ordering Code

5. Overall And Mounting Dimensions


Namkwang Centlex Room 412, 440-4 Cheongcheon-dong, Bupyeong-gu, Incheon 403-858, Korea.    E-Mail : sales@handouk.co.kr   TEL : 032-363-3800~4   FAX : 032-363-3805   Copyright 2009 @ HANDOUK Electronics Co. Ltd All Right Reserved.