HT22 Relay
|
¡Ü Only impulseexcitation is needed,both for single and double coil.
¡Ü Low
power consumption with great load capability.
¡Ü Accessories can be welded upon customers'
requirement
¡Ü RoHS
compliant
¡Ü Dimension:(52.0¥ª43.0¥ª22.0)mm
|
CONTACT DATA
Contact form |
SPST |
Contact resistance |
Max. 1.0m§Ù (1A 6VDC)
|
Contact material |
Silver alloy |
Contact rating (resistive load) |
100A 250VAC |
120A 250VAC |
Max.Switching Voltage |
250VAC
|
Max.Switching Current |
100A |
120A |
Max.Switching Power |
25KVA |
30KVA |
Mechanical life
|
5×105OPS
|
Electrical life
|
1×104OPS
|
Max.Short-circuit current
|
3000A/10ms |
3600A/10ms |
CHARACTERISTICS
Operate Time |
30ms Max |
Release Time |
30ms Max |
Relative humidity |
45%-90%RH |
Dielectric strength |
Coil contact |
4000VAC 50/60Hz (1 Min) |
between Open contacts |
2000VAC 50/60Hz (1Min) |
Insulation resistance |
500M§Ù Min.(500VDC)
|
Ambient temperature |
-40¡É~+70¡É |
Impulsion
|
98m/s2 |
Vibration
|
10-55HZ,1.5mm |
Weight (without accessorise)
|
68g |
Notes: When requiring
other nominal voltage, special order allowed.
COIL DATA
Rate coil(VDC)
|
Coil
resistance (§Ù)±10%
|
Coil Power (W)
|
Operate Voltage(VDC)
|
Release Voltage(VDC)
|
Over voltage (VDC)
|
Impulse Duration(ms)
|
Single coil
|
Double coil
|
Single coil
|
Double coil
|
6VDC
|
12
|
6/6
|
3.0W
|
6.0W
|
¡Â75%
|
¡Â75%
|
¡Â150%
|
¡Ã90ms
|
9VDC
|
27
|
13.5/13.5
|
12VDC
|
48
|
24/24
|
24VDC
|
192
|
96/96
|
48VDC
|
768
|
384/384
|
ORDERING INFORATION
OUTLINE
DIMENSIONS,AND WIRING DIAGRAM Unit:mm
Schematic diagram of a typical specifition Unit: mm
Remark :
1.
The factory default of the contacts is to
stay closure(reset), It¡¯s possible that the status will be changed with
Impact during shipment or installation. Pleasemake sure the status of the contacts stay reset before using.
2.
To
guarantee the latching relay operates reliably, the excitation voltage to coil
should meet the rated value and
Impulse duration needs to exceed 3 times of
the operation time. For double coil type latching relay. Please neither apply
Voltage signal to both coils at the same time
nor apply with long time(over 1 min).
3.
Latching
relays without copper braided wires, the loaded PIN can neither be tin soldered
nor be wrenched. Rigid
Fixing of the two pins is also not allowed.
4.
Magnetic
latching relay is polarized relay. If customer needs different kinds of
polarity from the data sheet,
please inform us.
5.
Please
handle the latching relays with care during factory¡¯s incoming-inspection and
when put in use, do not let
The relay drops which will impact the
parameter. Please make strict distinction between relay made for.
|