 HT4 Relay

* 100A switching capability.
* Strong resistance ability to shock & vibration
* Heavy load up to 27.7kVA
* 4kV dielectric strength between coil and contacts.
* Micro switch on mounting board available.

1. CONTACT DATA

Contact  Arrangement 1 Form A (SPST)
Voltage drop2) Typ.: 50mV (at 10A)
Max.:250mV (at 10A)
Contact material  AgSnO2, AgCdO
Contact  Ratings(Res. Load) 100A 277VAC/28VDC
Max Switching Voltage 440VAC / 45VDC
Max Switching Current 100A
Max Switching Power 27,700VA / 2,800W
Life Expectancy Electrical 2 x 104 ops
Machanical 1 x 105 ops

2. CHARACTERISTICS

Insulation Resistance 1,000M¥Ø
Dielectric strength between coil & contacts 4,000VAC 1 min.
open contacts 2,000VAC 1 min.
Creepage distance 8 mm
Operate time 20 ms max.
Release time 20 ms max.
Shock
resistance
Functional 100m/s2
Destructive 1,000m/s2
Viberation resistance 10Hz to 55Hz 1.0mm DA
Humidity 98% RH, 40°C
Ambient temperature -40°C ~ 70°C
Termination PCB & QC
Unit weight Approx 100g
Construction Dust protected

3. COIL DATA3) At 20¡É

Nominal voltage VDC Coil resistance ±10% ¥Ø Pick-up voltage VDC Pilse Duration
ms
Coil Power
Standard 6 Single coil 16 ¡Â4.8 200 2.4W
12 60 ¡Â9.6 200
24 250 ¡Â19.2 200
48 1,000 ¡Â38.4 200
6 Double coil 8+8 ¡Â4.8 200 4.8W
12 30+30 ¡Â9.6 200
24 125+125 ¡Â19.2 200
48 500+500 ¡Â38.4 200

Notes: 1) The data shown above are initial values.
          2) Equivalent to the max. initial contact resistance is 50m¥Ø (at 1A 24VDC), and measured
              when coil is energized with 100% nominal voltage at 25°C.
          3) When requiring other nominal voltage, special order allowed.

Notice
1. Relay is on the "set" status when being released from stock, with the consideration of shock risen
    from transit and relay mounting, relay would be changed to "reset" status, therefore,
    when application (connecting the power supply), please reset the relay to "set" or "reset" status
    on request.
2. In order to maintain "set" or "reset" status, energized voltage to coil should reach the rated
    voltage, impulse width should be 5 times more than "set" or "reset" time. Do not energize voltage
    to "set" coil and "reset" coil simultaneously. And also long energized time (more than 1 min)
    should be avoided.
3. The terminals of relay without twisted copper wire can not be tin-soldered, can not be moved
    willfully, more over two terminals can not be fixed at the same time.

4. Ordering Code

Notes: 1) When ordering sensitive type, please specify the exact coil power.
            2) HT4 is an environmental friendly product.

5. OUTLINE DIMENSIONS, WIRING DIAGRAM & PC BOARD LAYOUT (Unit : mm)


Remark : In case of no taloerance shown in outline dimension : Outline dimension¡Â 1mm, tolerance should be ±0.2mm; Outline dimension
             ¡µ 1mm and ¡Â 5mm, tolerance should be ±0.3mm; outline dimension ¡µ5mm, tolerance should be ±0.4mm.

Namkwang Centlex Room 412, 440-4 Cheongcheon-dong, Bupyeong-gu, Incheon 403-858, Korea.    E-Mail : sales@handouk.co.kr   TEL : 032-363-3800~4   FAX : 032-363-3805   Copyright 2009 @ HANDOUK Electronics Co. Ltd All Right Reserved.