ID:     PW:   
Korean English
ȸ»ç¼Ò°³ Á¦Ç°¾È³» ±â¼úÀÚ·á °Ô½ÃÆÇ ÆǸŴ븮Á¡ »çÀÌÆ®¸Ê

Telecom
Power
General Purpose
Automotive
SSR(Solid State Relay)
Time
etc
Home > Product > Power    
    Socket Packing Cross Reference
Power
HANDOUK LOGO
HT6 Magnetic Latching Relay
* 200A switching capability
* Strong resistance ability to shock & vibration
* Low coil consumption, ultra-low temperature rise
* Low contact resistance
* Environmental friendly product (RoHS compliant)
* Outline Dimensions(107.5 X 97.0X29.5)mm

CONTACT DATA

Contact  arrangement  2A / 2B
Contact resistance  1.0m¥Ø (at 1A 24VDC)
Contact  Material   AgSnO2, AgCdO
Contact  Rating(Res. load)  200A 250VAC / 30VDC
Max Switching Power  50,000VA
Mechanical endurance  5 X 103ops
Electrical endurance  5 X 105ops

CHARACTERISTICS

Insulation Resistance  1,000M¥Ø, Min. at 500VDC
Dielectric Strength
Between coil& Contacts  4,000VAC (for one minute)
Between open& Contacts  2,000VAC(for one minute)      
Operate Time(at nomi. volt)        50ms max.
Release Time(at nomi. volt)        50ms max.
Ambient Temperature   -40¡É to +70¡É
Shock Resistance Functional

 100m/s2 (10g)    

Destructive

 1,000m/s2 (100g)    

Vibration Resistance  10-55Hz, 1.5mmDA
Humidity  98%RH,40¡É
Ambient temperature  -40% to 85%
Termination  PCB & QC
Unit Weight  Approx .500g
Construction  Dust proofed
Coil power  Single Coil: 12W;   Double Coil: 24 W

COIL DATA

Nominal Voltage
VDC
Pick-up Voltage
VDC
Pulse Duration (ms) Coil Resistance(¥Ø) +/-10%
12 906 ¡Ã150 Single Coil

12

24 19.2 ¡Ã150

48

48 38.4 ¡Ã150

190

12 9.6 ¡Ã150 Double Coils

6+6

24 19.2 ¡Ã150

24+24

48 38.4 ¡Ã150

95+95

Notes:  When requiring other nominal voltage, special order allowed.

NOTICE

1. Relay is on the ¡°set¡± status hen being released from stock, with the consideration of shock risen from transit and relay mounting, relay would be changed to ¡°reset¡± status, therefore, when application(connecting the power supply), please reset the relay to ¡°set¡± or ¡°reset¡± status on request.

2. In order to maintain ¡°set¡± or ¡°reset¡± status, energized voltage to coil should reach the rated voltage, impulse width should be 5 times more than ¡°set¡± or ¡°reset¡± time. Do not energize voltage to ¡°set¡± coil and ¡°reset¡± coil simultaneously. And also long energized time (more than 1 min) should be avoided.

3. The terminals of relay without twisted copper wire can not be tin-soldered, can not be mover willfully, more over two terminals can not be fixed at the same time.

ORDERING INFORMATION

OUTLINE DIMENSIONS AND WIRING DIAGRAM                                                            Unit:mm

Remark:1) In case of no tolerance shown in outline dimension: outline dimension¡Â1mm,tolerance should be±0.2mm;outline dimension¡µ1mm and ¡Â5mm,tolerance should be ±0.3mm£»outline dimension >5mm ,tolerance should be± 0.4mm.

Remark: The polarity of Reverse polarity and Standard polarity is opposite.

Disclaimer
This datasheet is for the customer¡¯s reference. All the specifications are subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their for their own application. If there is any query, please contact HANDOUK for the technical service. However, it is the user¡¯s responsibility to determine which product should be used only.

Namkwang Centlex Room 412, 440-4 Cheongcheon-dong, Bupyeong-gu, Incheon 403-858, Korea.    E-Mail : sales@handouk.co.kr   TEL : 032-363-3800~4   FAX : 032-363-3805   Copyright 2009 @ HANDOUK Electronics Co. Ltd All Right Reserved.