HT6 Magnetic Latching Relay |
* 200A switching capability
* Strong resistance
ability to shock & vibration
* Low coil consumption, ultra-low temperature rise
* Low contact resistance
* Environmental
friendly product (RoHS compliant)
* Outline Dimensions(107.5 X 97.0X29.5)mm |
CONTACT DATA
Contact arrangement |
2A / 2B |
Contact resistance |
1.0m¥Ø (at 1A 24VDC) |
Contact Material |
AgSnO2, AgCdO |
Contact Rating(Res. load) |
200A
250VAC / 30VDC |
Max Switching Power |
50,000VA |
Mechanical endurance |
5 X 103ops |
Electrical
endurance |
5 X 105ops |
CHARACTERISTICS
Insulation
Resistance |
1,000M¥Ø, Min. at 500VDC |
Dielectric
Strength
|
Between coil& Contacts |
4,000VAC (for
one minute) |
Between open& Contacts |
2,000VAC(for one minute) |
Operate Time(at
nomi. volt) |
50ms max. |
Release Time(at
nomi. volt) |
50ms max. |
Ambient Temperature |
-40¡É to +70¡É |
Shock
Resistance |
Functional |
100m/s2 (10g)
|
Destructive |
1,000m/s2 (100g)
|
Vibration
Resistance |
10-55Hz,
1.5mmDA |
Humidity |
98%RH,40¡É |
Ambient temperature |
-40% to 85% |
Termination |
PCB & QC |
Unit Weight |
Approx
.500g |
Construction |
Dust proofed |
Coil power |
Single Coil: 12W; Double Coil: 24 W |
COIL DATA
Nominal Voltage
VDC |
Pick-up Voltage
VDC |
Pulse Duration (ms) |
Coil Resistance(¥Ø) +/-10% |
12 |
906 |
¡Ã150 |
Single Coil |
12
|
24 |
19.2 |
¡Ã150 |
48
|
48 |
38.4 |
¡Ã150 |
190
|
12 |
9.6 |
¡Ã150 |
Double Coils |
6+6
|
24 |
19.2 |
¡Ã150 |
24+24
|
48 |
38.4 |
¡Ã150 |
95+95
|
Notes: When requiring
other nominal voltage, special order allowed.
NOTICE
1. Relay is on the ¡°set¡± status hen being released
from stock, with the consideration of shock risen from transit and relay
mounting, relay would be changed to ¡°reset¡± status, therefore, when
application(connecting the power supply), please reset the relay to ¡°set¡± or ¡°reset¡±
status on request.
2. In order to maintain ¡°set¡± or ¡°reset¡± status,
energized voltage to coil should reach the rated voltage, impulse width should
be 5 times more than ¡°set¡± or ¡°reset¡± time. Do not energize voltage to ¡°set¡±
coil and ¡°reset¡± coil simultaneously. And also long energized time (more than 1
min) should be avoided.
3. The terminals of relay without twisted copper wire
can not be tin-soldered, can not be mover willfully, more over two terminals
can not be fixed at the same time.
ORDERING INFORMATION
OUTLINE
DIMENSIONS AND WIRING DIAGRAM Unit:mm
Remark:1)
In case of no tolerance shown in outline dimension: outline
dimension¡Â1mm,tolerance should be±0.2mm;outline dimension¡µ1mm and
¡Â5mm,tolerance should be ±0.3mm£»outline dimension >5mm
,tolerance should be± 0.4mm.
Remark: The
polarity of Reverse polarity and Standard polarity is opposite.
Disclaimer
This datasheet is for the customer¡¯s
reference. All the specifications are subject to change without notice.
We could not evaluate all the
performance and all the parameters for every possible application. Thus the
user should be in a right position to choose the suitable product for their for
their own application. If there is any query, please contact HANDOUK for the
technical service. However, it is the user¡¯s responsibility to determine which
product should be used only. |