HT9 Relay
* 60A switching capability
* 4Kv dielectric strength (between coil and contacts)
* Heavy load up to 15,000VA
* Environmental friendly product (RoHS compliant)
* Outline Dimensions(38.0X30.0X16.0)mm

CONTACT DATA

Contact  arrangement 1A
Contact resistance 2m¥Ø (at 1A 24VDC)
Contact  Material   AgSnO2, AgCdO,
Contact  Rating(Res. load) 60A 250VAC : 5,000cperations, 50A 250VAC : 10,000operations,
40A 250VAC : 100,000operations
Max Switching Voltage 250VAC
Max Switching Current 60A
Max Switching Power 1,5000VA
Mechanical endurance 1X106 ops,  Meter :1 X105 ops
Electrical endurance 1X105ops (at 40A250VAC)

CHARACTERISTICS

Insulation Resistance 1,000M¥Ø, Min. at 500VDC
Dielectric Strength
Between coil& Contacts 4,000VAC (for one minute)
Between open& Contacts 1,500VAC(for one minute)
Creepage distance 8mm
Operate Time(at nomi. volt)                                                     20ms max.
Release Time(at nomi. volt)   20ms max.
Ambient Temperature -40¡É to +85¡É
Shock Resistance Functional 98m/s2
Destructive 980m/s2
Vibration Resistance 10-55Hz, 1.5mmDA
Humidity 98%RH,40¡É
Ambient temperature -40% to 70%
Termination PCB&QC
Unit Weight Wash tight,Approx.33g
Construction Wash tight, Dust proofed
Coil power Single Coil: 1.0W;   Double Coil: 2.0W

Notes:  When requiring other nominal voltage, special order allowed.

SAFETY APPROVAL RATINGS  

UL & CUL 40A 250VAC at 70¡É 50A 250VAC at 70¡É 60A 250VAC at 70¡É

Notes: Only some typical ratings are listed above. If more details are required, please contact us.

COIL DATA

Nominal
Voltage VDC
Pick-up
Voltage VDC
Pulse
Duration ms
Coil
Resistance¥Ø
5 3.5 50 Single Coils           24
6 4.2 50 35
9 6.3 50 80
12 8.4 50 145
24 16.8 50 575
48 33.6 50 2,270
5 3.5 50 Double Coils 12+12
6 4.2 50 17.5+17.5
9 6.3 50 40+40
12 8.4 50 72+72
24 16.8 50 285+285
48 33.6 50 1,135+1,135

Notes:  When requiring other nominal voltage, special order allowed.

ORDERING INFORMATION

Notes : 1) Under the ambience with dangerous gas like H2S, SO2 or NO2, wash tight type recommended; Please test the relay in real applications. If the ambience allows, dust protected type is preferentially recommended.

OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT             Unit:mm


HT9-**-**-1                                HT9-**-**-2                                 HT9-**-**-3

                                                   HT9-**-**-4                                 HT9-**-**-5

Remark:
1) In case of no tolerance shown in outline dimension : outline dimension¡Â1mm,tolerance should be±0.2mm;outline dimension ¡µ1mm and 5mm, tolerance should be ±0.3mm£»outline dimension >5mm ,tolerance should be± 0.4mm.

2) The tolerance without indicating for PCB layout is always ±0.1mm.

Note :
1. Melt both ends of the wire at 5mm,  then weld it together with copper plate and relay Terminals(anti-tensile strength¡Ã50N)
2. Weld the copper plate with flex wire, the anti-tensile strength should be 50N, please see The sketch map from right side to left side
3. The welding direction of flex wire should be orientated to state-spring.
4. ORDERING INFORMATION: HT9-XX-ST-1-R  A  50 / 80
       Welding sketch map : A Type
       The length of flex wire
       - The length of right side flex wire L1 = 50mm :
       - The length of right side flex wire L2 = 50mm :

Notes: We can make special connection according to customer¡¯s requirement.
Please provide us with the drawing, and shunt specification

Remark : 1) In case of no tolerance shown in outline dimension: outline dimension¡Â1mm, tolerance should be ±0.2mm; outline
            dimension>1mm and¡Â5mm, tolerance should be±0.3mm; outline dimension>5mm, tolerance should be ±0.4mm.
         2) The tolerance without indicating for PCB layout always ±0.1mm.

Notice
1. Relay in on the "set" status when being released from stock, with the consideration of shcok risen from transit and relay mounting, relay would be changed to "reset" status, therefore, when application (connecting the power supply), please reset the relay to "set" or "reset" status on request.
2. In order to maintain "set" or "reset" status, energized voltage to coil should reach the rated voltage, impulse width should be 5 times more than "set" or "reset" time. Do not energize to "set" coil and "reset" coil simultaneously. And also long energized time (more than 1 min.) should be avoided.
3. The terminals of relay without flex wire can not be tin-soldered, can not be moved willfully, more over two terminals can not be fixed at the same time.