BA3
Relay |
● Offer excellent board space savings
● Surge withstand voltage up to 1,500V
Meets FCC Part
68
● High contact capacity 2A 30VDC
● Low power consumption
● Single side stable and latching type available
● Single or double coil winding type available
●UL 197546
(14
x 9 x 5.4mm)
|
1. 일반 사양
접점구조 |
2 Form C (Bifurcated Crossbar) |
접촉
저항 |
≤ 100 mΩ (at 10mA 30mVDC)
|
접점 재질 |
AgPd + Au plated, AgNi + Au plated
|
정격
접점 용량 (저항부하) |
1A 30VDC, 2A 30VDC, 0.5A/120VAC
|
최대
개폐력 |
30W DC / 62.5VA |
최대
개폐 전압 |
220VDC / 250VAC |
최소 가용 전류 |
0.01mA/10mV(Reference Value)
|
최대
개폐 전류 |
2A DC/AC |
구
조 |
PCB Terminal |
SMD Terminal |
외곽
치수 (mm) |
14.0 × 9.0 × 5.4mm |
14.0 x 11.2(9.1) x 6.25 |
최소
수명 |
기계적 |
1 x 108 |
전기적 |
1×105 ops (0.5A 125VAC, Resistive load,
AgNi + Au plated, at 70℃, 1s on 9s off)
|
Notes: 1) The data shown above are
initial values. 2) Min. applicable load is reference value. Please perform the
confirmation test with the actual load before production since reference value
may change according to switching frequencies, environmental conditions and
expected contact resistance and reliability. 3) Electrical endurance test is
conducted with load being connected to NO or NC contacts.
2. 동 작 특 성
절연 저항 |
1000MΩ min. at 500V DC |
Dielectric
Withstand Voltage between |
접점 간 |
750V AC for 1 minute |
접점 코일 간 |
1500V AC for 1 minute |
접점조 간 |
1500V AC for 1 minute |
Surge withstand voltage between open contacts(10/160µs)
|
1,500VAC (FCC part 68) |
동작 시간 (Set time) |
Approx. 3ms |
복귀
시간 (Reset time) |
Approx.3ms |
주위 온도 |
-40~70℃(-40~158°F)
|
주위 습도 |
5% to 85% RH
|
충격
저항 |
기능적 |
735m/s2 |
파괴적 |
980m/s2 |
진동 저항 |
10~55Hz 3.0mm DA |
Termination |
DIP, SMT |
Moisture sensitivity levels (Only for SMT type, JEDEC-STD-020) |
MSL-3 |
Construction |
Plastic sealed |
Unit weight
|
1.8g |
UL/CUL |
AgNi + Au plated
|
1A 30VAC (70℃),2A 30VAC (40℃),
0.5A 110VDC (70℃), 0.5A
125VAC (70℃)
|
Notes: 1) The data shown above
are initial values. 2) UL insulation system : Class A.
3. 형태 및 코일 사양 at at 20°C (68°F)
Single Side Stable |
Relay Code |
정격전압(VDC) |
코일저항(Ω±10%) |
동작전압(VDC) |
복귀전압(VDC) |
정격소비전류(W
DC) |
최대가용전압(VDC) |
BA3-1.5 |
1.5 |
16 |
1.13 |
0.15 |
0.14 |
3.0 |
BA3-2.4 |
2.4 |
41.3 |
1.8 |
0.24 |
0.14 |
4.8 |
BA3-3 |
3 |
64.3 |
2.25 |
0.3 |
0.14 |
6.0 |
BA3-4.5 |
4.5 |
145 |
3.38 |
0.45 |
0.14 |
9.0 |
BA3-5 |
5 |
178 |
3.75 |
0.5 |
0.14 |
10.0 |
BA3-6 |
6 |
257 |
4.50 |
0.6 |
0.14 |
12.0 |
BA3-9 |
9 |
579 |
6.75 |
0.9 |
0.14 |
18.0 |
BA3-12 |
12 |
1028 |
9.00 |
1.2 |
0.14 |
24.0 |
BA3-24 |
24 |
2880 |
18 |
2.4 |
0.20 |
48.0 |
1 Coil Latching |
Relay Code |
정격전압(VDC) |
코일저항(Ω±10%) |
Set Voltage(VDC) |
Re-set Voltage(VDC) |
정격소비전류(W
DC) |
최대가용전압(VDC) |
BA3-1.5L |
1.5 |
22.5 |
1.13 |
-1.13 |
0.10 |
3.0 |
BA3-2.4L |
2.4 |
58 |
1.8 |
-1.8 |
0.10 |
4.8 |
BA3-3L |
3 |
90 |
2.25 |
-2.5 |
0.10 |
6.0 |
BA3-4.5L |
4.5 |
203 |
3.38 |
-3.38 |
0.10 |
9.0 |
BA3-5L |
5 |
250 |
3.75 |
-3.75 |
0.10 |
10.0 |
BA3-6L |
6 |
360 |
4.50 |
-4.50 |
0.10 |
12.0 |
BA3-9L |
9 |
810 |
6.75 |
-6.75 |
0.10 |
18.0 |
BA3-12L |
12 |
1440 |
9.00 |
-9.00 |
0.10 |
24.0 |
BA3-24L |
24 |
3840 |
18.0 |
-18.0 |
0.15 |
48.0 |
2 Coil Latching |
Relay Code |
정격전압(VDC) |
코일저항(Ω±10%) |
Set Voltage(VDC) |
Re-set Voltage(VDC) |
정격소비전류(W
DC) |
최대가용전압(VDC) |
BA3-1.5K |
1.5 |
11.3 |
1.13 |
1.13 |
0.20 |
3.0 |
BA3-2.4J |
2.4 |
29 |
1.8 |
1.8 |
0.20 |
4.8 |
BA3-3K |
3 |
45
|
2.25 |
2.25 |
0.20 |
6.0 |
BA3-4.5K |
4.5 |
101 |
3.38 |
3.38 |
0.20 |
9.0 |
BA3-5K |
5 |
125
|
3.75 |
3.75 |
0.20 |
10.0 |
BA3-6K |
6 |
180
|
4.50 |
4.50 |
0.20 |
12.0 |
BA3-9K |
9 |
405
|
6.75 |
6.75 |
0.20 |
18.0 |
BA3-12K |
12 |
720
|
9.00 |
9.00 |
0.20 |
24.0 |
BA3-24K
|
24 |
1,920
|
18.0 |
18.0 |
0.30 |
48.0 |
Notes:
1) Energizing coil with rated voltage is basic for normal operation of a
relay. Please make sure the energized voltage to relay coil have reached the
rated voltage. 2) In case 5V of transistor drive circuit, it is recommended to
use 4.5V type relay, and 3V to use 2.4V type relay. 3) For monostable relays,
if you need to drop down voltage and hold mode after reliably operating, make
sure that the effective value of holding voltage is not less than 60% of the
rated voltage. 4) Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time. 5) When user’s requirements can’t
be found in the above table, special order allowed.
4. 주문 코드
Notes: 1) R type (Tape and
reel) packing is moisture-proof which meets requirement of ML-3. Please choose
R type packing for SMT products. For R type, the letter “R” will only be
printed on packing tag but not on relay cover. Tube packing is normally not
available for SMT products unless specially requested by customer. But please
note that tube packing is not moisture-proof so please bake the products before
use according to description of notice 11 herewith. In addition, tube packing
will be adopted when the ordering quantity of R type is equal to or less than
100pcs unless otherwise specified. 2) The customer special requirement express
as special code after evaluating by HANDOUK. 3) Standard tube packing lenth is
580mm. Any special requirements needed, please contact us for more details. 4)
For products that should meet the explosion-proof requirements of “IEC60079
series”, please note (EX) after the specification while placing orders. Note
all products have explosion-proof certification, so please contact us if
necessary, in order to select the suitable products.
5. 외관 및 장착 규격
PCB Terminal
6. 포장 사양
7. SPLDERING 조건
Notes: 1) Temperature profile shows Printed Circuit
Board surface temperature on the relay terminal portion. 2) Please check the
actual sodering condition to use other method except above mentioned
temperature profiles.
8. 특성 곡선
NOTES
1). this relay is highly sensitive polarized relay, if
correct polarity is not applied to the coil terminals; the relay does not
operate properly.
2). To avoid using relays under strong magnetic
field which will change the parameters of relays such as pick-up voltage and
drop out voltage.
3). Relay is on the “reset” status when being released from stock, with the
consideration of shock risen from transit and relay mounting, it should be
changed to the “set” status when application(connecting to power supply).
Please reset the relay to “set” or “reset” status on request.
4). Energizing coil with rated voltage is basic for normal operation of a
relay, please make sure the energized voltage to relay coil have reached the
rated voltage. Regarding latching relay, in order to maintain the “set” or “reset”
status, impilse width of the rated voltage applied to coil should be more than
5 times of “set” and “reset” time.
5). For a monosteady state relay, after the relay is reliably operated, if itneeds to be kept under pressure, make sure that the effective value of the
voltage is not less than 60% of the rated voltage.
6). For 2 coil latching relay, do not energized voltage to “set” coil and “reset”
coil simultaneously.
7). The relay may be damaged because of falling or when shocking conditions
exceed the requirement.
8). For SMT products, validation with real application should be done
before your series production. If the reflow-soldering temperature curve is out
of our recommendation. Generally, two time reflow-soldering is not recommended
for the relay. However, if two time reflow-soldering is required, a 60-min.
interval should be guaranteed and validation should be done before production.
9). Please use wave soldering or manual soldering for straight-in relay. If
you need reflow welding, please confirm the feasibility with us.
10). Contact is recommended for suitable condition and specifications if
water cleaning or surface process is involved in assembling relays on PCB.
11). Regarding the plastic sealed relay, we should leave it cooling
naturally below 40℃ after welding, then clean it and deal with coating,
remarkably the temperature of solvents should also be controlled below 40℃. Please avoid cleaning the relay by ultrasonic, avoid using the solvents
like gasoline, Freon, and so on, which would affect the configuration of relay
or influence the environment.
12). Relays packaged in moisture barrier bags meet MSL-3 requirements. The
relays should be stored at ambient condition of 30℃ and ≤60% RH after they are removed from their package, and
should be used within 168 hours. If the relay cannot be used within 168 hours,
please repack them or store them in a drying oven at 25℃±5℃, ≤10% RH. Otherwise, relays may be subjected to a
soldering test to check their performance, or they may be used after keeping
them in an oven for 72 hours at with 50℃±5℃, ≤30% RH.
13). When applied with continuous current, the heat from relay coil will
age its isolation. Thus, please do not ground connected the coil to reduce
electrical erosion if possible. And please provide protection circuit to avoid
broken wire and losses.
14). Please make sure that there are no silicon-based substances (Such as
silicon rubber, silicon oil, silicon-based coating agents, silicon fillers,
etc.) around the relay, because it will generate silicon-containing volatile
gas, which may cause poor contact in case of silicon-containing volatile gas
sticking on contact.
15). About preferable condition of operation, storage and transportation,
please refer to “Explanation to terminology and guidelines of relay”.
Disclaimer
The specification is for reference only. Specifications subject to change
without notice.
We could not evaluate all the performance and all the parameters for every
possible application. Thus the user should be in a right position to choose the
suitable product for their own application. If there is any query, please
contact Handouk for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Handouk Electronics Co., Ltd.
All rights of Handouk are reserved.
|